Yangzhou Aiweite Electromechanical Co., Ltd. manufactures 100kVA – 400kVA Universal Diesel Generator Sets for commercial, industrial, medical, municipal and infrastructure standby power. The series is built around mainstream medium-bore diesel engines, heavy-duty brushless alternators and upgraded intelligent control systems.
Mid-Power Gensets Engineered for Continuous Duty
Our 100kVA – 400kVA range bridges small backup units and heavy industrial power. It is designed for prime power, long-duration standby and frequent load fluctuation, with stronger overload resistance and better voltage stability than small-power gensets. The series complies with ISO 8528 and GB/T 2828 performance requirements and is widely applied in commercial complexes, medium manufacturing sites and municipal engineering projects.
Each unit is configured around the actual working point: load profile, ambient conditions, altitude, fuel quality and the required operating mode. We supply open, silent, container and trailer structures, with 50Hz or 60Hz electrical configuration and global voltage standards.
Core Configuration of the 100kVA – 400kVA Series
Engine
Mainstream medium-bore industrial diesel engines with turbocharged intercooling and high-precision fuel injection. Sufficient power reserve, strong instantaneous load response and stable continuous operation in high-temperature, high-humidity, dusty and high-altitude environments.
Alternator
Heavy-duty brushless synchronous full-copper alternator, Class H insulation, IP23 protection. Large power margin, low waveform distortion and excellent dynamic performance for mixed resistive and inductive loads.
Control System
Industrial-grade intelligent controller with fault diagnosis and multi-protection. Supports automatic start/stop, ATS switching, real-time monitoring, remote cloud management and multi-unit parallel operation for 24/7 unattended operation.
Auxiliary System
Reinforced integrated base frame, large-flow cooling system, high-efficiency multi-stage filtration, heavy-duty shock absorption and industrial silencer. Modular design for convenient installation and low daily maintenance frequency.
Available Range and Structure Options
We build the 100kVA – 400kVA series in four structural formats and with a choice of engine brands. The table below shows how each configuration is positioned for project use.
| Configuration |
Typical Application |
Key Selection Notes |
| Open type |
Factory workshops, temporary power, plant rooms with dedicated acoustic treatment |
Lowest footprint and cost; requires ventilated, weather-protected room |
| Silent type |
Hospitals, hotels, office buildings, residential-adjacent commercial sites |
Acoustic canopy with noise reduction; confirm required dB(A) at distance |
| Container type |
Data rooms, regional communication base stations, outdoor municipal projects |
Weatherproof, transportable; integrated fuel tank and control room options |
| Trailer type |
Construction sites, bridge and road engineering, temporary industrial parks |
Mobility with road-towable chassis; confirm axle and braking requirements |
Engine Brand Options Within the Series
The 100kVA – 400kVA platform is compatible with all mainstream diesel engine brands. We select the engine according to fuel availability, service network, emission requirements and load profile. Available engine families include:
- Cummins Powered Diesel Generator Sets — global spare parts and service coverage
- Perkins Powered Diesel Generator Sets — proven medium-bore industrial platform
- Weichai Powered Diesel Generator Sets — strong domestic supply chain and cost efficiency
- Yuchai Powered Diesel Generator Sets — robust performance in high-load conditions
- Baudouin Powered Diesel Generator Sets — marine-derived durability for harsh environments
- MTU Powered Diesel Generator Sets — high-performance option for critical standby
- Volvo Powered Diesel Generator Sets — low emissions and smooth operation
- SDEC Powered Diesel Generator Sets — cost-effective mid-power solution
- Mitsubishi Powered Diesel Generator Sets — compact and reliable for commercial use
Application Fit Across Industries
This mid-power series is the most widely used universal genset for medium-scale power demand. Typical installations include:
- Commercial complexes: shopping malls, supermarkets, office buildings, hotels, resorts and exhibition centers — backup power for daily operations, central air conditioning and emergency lighting.
- Medical and educational institutions: hospitals, medical centers, universities and campus parks — uninterrupted power for medical equipment, teaching systems and safety monitoring.
- Municipal and public facilities: traffic facilities, water supply and drainage projects, energy stations and public service centers — reliable emergency and standby power.
- Medium industrial and manufacturing sites: processing factories, workshop production lines and packaging enterprises — preventing production shutdown losses during grid failure.
- Construction and engineering projects: urban construction sites, bridge engineering, road construction and temporary industrial parks — stable temporary power supply.
- Communication and data infrastructure: medium data computer rooms, regional communication base stations and network operation centers — stable operation of IT equipment and servers.
Controls, Automation and Line Integration
We configure the control system around the required line interface. The industrial-grade controller supports automatic start/stop, ATS automatic switching, real-time data monitoring, remote cloud management and multi-unit parallel operation. For projects requiring integration with building management systems or SCADA, we confirm communication protocol, alarm mapping and remote monitoring requirements during engineering review.
Electrical configuration is matched to site conditions: 50Hz or 60Hz, global voltage standards, and protection settings coordinated with upstream switchgear. Where the generator operates in parallel with other units or with the grid, we define the synchronization and load-sharing strategy before production.
Quality Control and Acceptance Testing
Every 100kVA – 400kVA genset is validated through a structured quality process before delivery. Control points include incoming inspection of key components, assembly process verification, electrical safety checks and mechanical fitting inspection. Before shipment, each unit undergoes full-load testing from 0–110% rated capacity, step load response testing, continuous operation endurance testing, voltage and frequency stability testing, and emergency protection system verification.
We document test results and provide them with the delivery package. For projects requiring third-party inspection or witness testing, we coordinate the acceptance protocol during order confirmation.
Installation, Maintenance and Serviceability
The reinforced integrated base frame and modular layout simplify installation. We provide installation guidance covering foundation requirements, ventilation, exhaust routing, fuel system connection and electrical termination. Daily maintenance focuses on filters, lubricating oil, coolant and battery condition; the multi-stage filtration system and accessible component layout reduce service time.
We supply genuine spare parts for engine components, alternator parts, electrical and control system parts, filters and consumables. Technical troubleshooting and operation support are available after installation.
Information We Use to Configure Your Solution
To prepare an accurate configuration and quotation for a 100kVA – 400kVA genset, we need the following project inputs:
- Required power rating (kVA/kW) and operating mode: standby, prime or continuous
- Site conditions: ambient temperature, humidity, altitude, dust level and installation environment
- Load profile: type of loads, starting method, step load size and power factor
- Electrical parameters: voltage, frequency, phase and number of wires
- Control and automation requirements: ATS, remote monitoring, parallel operation, communication protocol
- Structure preference: open, silent, container or trailer
- Engine brand preference or fuel quality constraints
- Applicable standards, inspection requirements and documentation language
- Delivery destination, packaging requirements and expected project schedule
Frequently Asked Questions
What is the difference between the 100kVA – 400kVA series and smaller gensets?
This series uses medium-bore industrial engines with turbocharged intercooling, larger alternators and upgraded control systems. It delivers stronger overload resistance, better voltage stability and higher continuous working reliability, making it suitable for medium-scale commercial, industrial and municipal projects.
Can you supply the genset with a specific engine brand?
Yes. The platform is compatible with Cummins, Perkins, Weichai, Yuchai, Baudouin, MTU, Volvo, SDEC and Mitsubishi engines, among others. We select the engine based on fuel availability, service network, emission requirements and load profile.
What testing is performed before delivery?
Each unit undergoes full-load testing from 0–110% rated capacity, step load response testing, continuous operation endurance testing, voltage and frequency stability testing, and emergency protection system verification. Test documentation is included with the delivery package.
Do you support OEM/ODM customization for this power range?
Yes. We provide OEM and ODM generator manufacturing solutions covering power configuration, engine selection, control system integration, structural design and acoustic treatment. Customization is based on customer specifications, engineering requirements and application environments.
What is the typical lead time for a 100kVA – 400kVA genset?
Lead time depends on configuration, engine availability and project schedule. We confirm production scheduling during order review and coordinate delivery to meet project milestones.
What support is available after installation?
We provide installation guidance, operation support, technical troubleshooting and genuine spare parts supply. Our service system is designed to ensure stable operation and long-term reliability throughout the generator set lifecycle.