About Aiweite
Founded in 2008, Yangzhou Aiweite Electromechanical Co., Ltd. has accumulated extensive experience in the manufacture and installation of generator sets ranging from 1 kVA to 2,500 kVA. We are China Open/Silent/Trailer/Container Type Diesel Generator Suppliers and Custom Open/Silent/Trailer/Container Type Diesel Generator Exporter, Company. Over the years, Aiweite has continued to strengthen its capabilities and market presence, and we are committed to becoming a reliable long-term partner for customers worldwide.
Through continuous innovation, we consistently improve the efficiency, durability, and environmental performance of our products. Advanced manufacturing equipment and strict quality management are applied throughout production to ensure that every generator set meets applicable international standards.
We have established long-term and stable relationships with customers across different markets and place strong emphasis on customer satisfaction. Comprehensive support is provided before, during, and after each project, ensuring that customer requirements are addressed promptly and effectively.
Guided by the principle of "Quality First, Customer First," we uphold a corporate culture built on integrity, responsibility, innovation, and mutual success.
Certificate
Latest Updates
Industry knowledge
Yangzhou Aiweite Electromechanical Co., Ltd. builds diesel generator sets from 1 kVA to 2,500 kVA and has manufactured and installed generating equipment since 2008. Within this product family we supply four structural formats — open, silent, trailer and container — so a project can be matched to its enclosure, mobility, noise and installation conditions rather than forced into one housing type.
Our work covers generator production, system integration and installation for industrial, commercial and infrastructure applications. Each set is assembled from a selected engine, alternator, controller, cooling package and base frame, then verified before dispatch. the category sets out the range we offer as a Open/Silent/Trailer/Container Diesel Generator Suppliers and the project inputs we use to configure a set.
Structure is usually the first decision after power rating, because it determines noise level, weather protection, transport method and maintenance access. We build all four formats on the same engine, alternator and control platform, so electrical performance is consistent across the range and the choice is driven by site conditions.
Bare set on an integrated base frame with exposed engine, alternator and radiator. Best heat dissipation, lowest cost, fastest inspection. Suited to indoor generator rooms, mines, processing plants and central power stations with ventilation and noise control already in place.
Enclosed canopy with muffler and sound-absorbing lining, weatherproof and dustproof. For residential areas, hotels, offices, hospitals and schools where noise limits and appearance matter.
Mobile set on a road-tow chassis for construction sites, road and rail works, events and rental fleets where the unit must move between locations.
ISO-footprint enclosure for larger ratings, outdoor fixed stations, data centres and remote sites needing secure, weather-protected, transportable housing.
| Format | Noise & Weather | Typical Installation | Main Application |
|---|---|---|---|
| Open | No enclosure; needs room ventilation and site noise measures | Indoor machine room, concrete plinth | Factories, mines, chemical plants, parallel power stations |
| Silent | Soundproof canopy, ≤75 dB(A) at 1 m, rain and dust protected | Outdoor pad or enclosed room | Residential, commercial, hospitals, schools |
| Trailer | Canopy plus tow chassis, brakes and road lighting as specified | Mobile, repositioned between sites | Construction, road and rail works, rental, events |
| Container | ISO enclosure, lockable, weather and dust protected | Outdoor fixed station, skid or foundation | Data centres, utilities, remote and high-rating sites |
The structural format sits on top of a power and engine selection. We build sets across the full 10 kVA–2500 kVA band and can match the engine brand to the duty, fuel quality and service network available at the site. Engine options include Cummins, Perkins, Volvo, MTU, Weichai, Yuchai, Baudouin and SDEC platforms.
Where a project spans several ratings, the same platform can be ordered across the Diesel Generator By Power Range bands, which keeps spares, control logic and operator training consistent across a fleet.
Format selection follows the site, not the catalogue. The points below are the conditions that most often decide the outcome.
We configure the control system around the required line interface. For standby duty this normally means mains monitoring, automatic transfer switching and a programmable cool-down cycle; for prime or continuous duty it means load management, alarm and shutdown protection, and remote monitoring where the site is unmanned.
Our production is organised around generator system integration rather than general assembly. Engine and alternator integration, canopy fabrication and modular assembly for different power ranges run through a unified workflow, with control points at incoming inspection, assembly verification, electrical safety checks and mechanical fitting inspection.
Before delivery, each set goes through performance validation: full-load testing from 0 to 110% of rated capacity, step-load response, continuous operation endurance, voltage and frequency stability, and emergency protection verification. Aiweite holds ISO 9001 quality management and ISO 14001 environmental management system certification.
Installation requirements differ by format, and we confirm them before the set leaves the works so that site preparation is not left to chance.
Service access is a design decision. Open sets expose all core components for inspection and fault finding without removing panels; silent and container sets use access doors sized for filter, belt and battery work. We supply genuine spare parts for engine components, alternator parts, electrical and control system parts, filters and consumables, and provide installation guidance, operation support and technical troubleshooting after commissioning.
Our OEM and ODM work covers full system customisation: power configuration, engine selection, control system integration and structural design. Typical customisation includes branded production, canopy and acoustic design for specific noise targets, electrical configuration for 50 Hz or 60 Hz markets, and operating mode selection for standby, prime or continuous duty.
For engine-specific builds, the range is organised under Diesel Generator By Engine, including Cummins Powered Diesel Generator Sets and Perkins Powered Diesel Generator Sets.
| Input | What It Determines |
|---|---|
| Load list and starting method | Rating, alternator size and step-load capability |
| Duty mode (standby / prime / continuous) | Engine rating, cooling package and fuel capacity |
| Site conditions and noise limit | Structural format, canopy design and exhaust routing |
| Grid voltage, frequency and phase | Electrical configuration and switchgear |
| Control and monitoring requirements | Controller brand, ATS, remote monitoring, paralleling |
| Transport and destination | Canopy dimensions, trailer specification, packing scope |
A silent or container set. Both use a sealed canopy with muffler and sound-absorbing lining, and our silent range is controlled within ≤75 dB(A) at 1 m. Container format is normally chosen when the rating is larger or the site needs a lockable, transportable enclosure.
The electrical core is shared across formats, so an open set can be re-housed where dimensions and cooling allow. In practice it is more economical to specify the final format at the outset, because canopy sizing, exhaust routing and access doors are designed together with the set.
We manufacture and install generator sets from 1 kVA to 2,500 kVA. The structural range is commonly supplied from 10 kVA to 2,500 kVA, and OEM/ODM projects can be configured from 10 kVA to 4,000 kVA depending on engine and alternator selection.
Every unit undergoes full-load testing from 0 to 110% of rated capacity, step-load response testing, continuous operation endurance testing, voltage and frequency stability checks, and emergency protection system verification.
Yes. We supply engine components, alternator parts, electrical and control system parts, filters and consumables, and provide installation guidance, operation support and technical troubleshooting after commissioning.
A load list with starting methods, the required duty mode, site conditions and noise limit, grid voltage and frequency, control and monitoring requirements, and the destination and transport constraints. With those inputs we can define the format, rating, engine, alternator and control package.