Yangzhou Aiweite Electromechanical Co., Ltd. manufactures Silent Type Diesel Generator Sets manufacturer range from 10kVA to 2500kVA, built on fully sealed soundproof canopies with integrated mufflers and multi-layer sound-absorbing structures. These units are upgraded from open-type platforms and comply with ISO 8528 industrial standards, combining noise control with weatherproof and dustproof enclosure performance.
We supply enclosed gensets for civil, commercial and public standby power where operating noise is a design constraint: residential communities, hotels, hospitals, schools, business parks and urban temporary power. Every set is assembled, wired and load-tested in our Yangzhou factory before shipment.
What Defines Our Silent Type Range
A silent genset is not an open unit with a box around it. The canopy, air path, exhaust routing and alternator cooling are engineered together so that acoustic performance does not compromise thermal performance. Our enclosed design maintains efficient heat dissipation through optimized air intake and exhaust, supporting long-term standby and continuous duty.
- Noise control: multi-layer sound absorption holds operating noise within ≤75dB(A) at 1 meter, meeting urban environmental and noise-limit requirements.
- All-weather enclosure: fully sealed canopy delivers dustproof, rainproof and sunproof protection for outdoor installation without extra shelters.
- Integrated appearance: compact enclosed structure suits standardized installation in buildings, commercial zones and public facilities.
- System compatibility: supports ATS switching, remote monitoring and multi-unit parallel operation across the full power range.
Power Range and Engine Matching
The silent canopy platform is compatible with all mainstream engine brands and the complete 10kVA–2500kVA power band. Engine selection drives fuel consumption, service intervals, load acceptance and spare-parts logistics, so we confirm the engine brand against the duty profile rather than the enclosure alone.
| Configuration Area |
Options We Build |
Typical Fit |
| Power output |
10kVA – 2500kVA, standby / prime / continuous |
Community backup, plant standby, temporary site power |
| Engine brand |
Cummins, Perkins, Volvo, MTU, Weichai, Yuchai, Baudouin, SDEC, Mitsubishi |
Fleet standardization and local service coverage |
| Electrical configuration |
50Hz / 60Hz, global voltage standards |
Export projects and mixed-voltage sites |
| Control system |
Deep Sea, SmartGen, ComAp or customer-specified |
AMF panels, remote monitoring, parallel operation |
| Acoustic design |
Canopy insulation build-up and muffler grade |
Urban, hospital and residential noise limits |
Application Fit by Site Type
Residential and Community Backup
Urban communities, villas and residential zones use the enclosed canopy to keep night-time test runs and outage starts within acceptable noise limits. Where the set sits close to occupied buildings, we review exhaust direction and air discharge orientation during layout.
Commercial and Public Facilities
Hotels, shopping malls, offices, hospitals, schools, libraries and government buildings require quiet, uninterrupted standby power. For medical and data-critical loads, step-load response and voltage/frequency stability matter more than steady-state rating alone.
Outdoor and Temporary Installations
Urban construction, road renovation and temporary outdoor supply benefit from the weatherproof enclosure, which removes the need for a separate protective structure. Outdoor fixed stations and closed machine rooms are both workable when ventilation openings are sized to the canopy air path.
Controls, Interfaces and Automation Integration
We configure the control system around the required line interface. Standard builds use Deep Sea, SmartGen or ComAp controllers; customer-specified control platforms are supported for fleet standardization. ATS switching, remote monitoring and multi-unit parallel operation are available across the range.
- AMF / ATS logic for mains failure start and transfer
- Remote monitoring and alarm signalling for unattended sites
- Parallel operation for capacity growth or redundancy
- Protection settings matched to the load and cable schedule
Installation, Utilities and Service Access
The integrated canopy increases overall dimensions and floor area compared with an open set of the same rating, so foundation and clearance planning should start early. Canopy doors provide access for daily inspection and servicing; we recommend leaving working space on the service side and keeping air intake and discharge paths clear.
Fuel supply, exhaust termination, cabling and earthing are coordinated with the site package. Installation guidance is part of our project support, and we supply genuine spare parts — engine components, alternator parts, electrical and control components, filters and consumables — to keep maintenance intervals predictable.
Quality Control and Acceptance Testing
Quality control runs through production rather than sitting at the end of the line. Incoming inspection of key components, assembly process verification, electrical safety checks and mechanical fitting inspection are applied across batches. Before delivery, each set goes through full-load testing from 0–110% rated capacity, step-load response testing, continuous operation endurance testing, voltage and frequency stability testing, and emergency protection system verification.
Aiweite has held ISO 9001 quality management and ISO 14001 environmental management certification, and our silent sets are built to ISO 8528 industrial standards. Test records and inspection documentation accompany the delivery scope so acceptance can be completed against agreed criteria.
Related Ranges We Manufacture
Silent canopies are one structural option within a wider build programme. If the site allows an exposed installation, an open set reduces cost and improves service access; where mobility or long-distance deployment is required, other structures apply.
Information We Use to Configure Your Solution
Our proposal is based on the working point, material and production target of the site. The more precisely the following inputs are defined, the more accurately we can size the set and fix the enclosure build.
- Load profile: total kW, starting method, largest motor step, power factor and whether duty is standby, prime or continuous.
- Electrical interface: voltage, frequency, phase, ATS or AMF requirement, parallel operation and remote monitoring protocol.
- Site conditions: indoor or outdoor placement, ambient temperature, altitude, available footprint and noise limit at the nearest receptor.
- Engine preference: preferred brand, service network and spare-parts availability in the destination market.
- Project scope: documentation language, inspection and acceptance requirements, packaging and delivery terms.
Frequently Asked Questions
What noise level do your silent type diesel generator sets achieve?
Our enclosed sets use multi-layer sound absorption and integrated mufflers to hold operating noise within ≤75dB(A) at 1 meter. Final figures depend on rating, canopy build and measurement position, so we confirm the target against the site noise limit during configuration.
Can a silent canopy be supplied on any engine brand and power rating?
Yes. The silent platform is compatible with all mainstream engine brands and covers 10kVA to 2500kVA. We match the canopy and cooling package to the selected engine and alternator rather than using a single universal enclosure.
Do you support ATS, remote monitoring and parallel operation?
We build these functions into the control system as required. Deep Sea, SmartGen and ComAp controllers are standard options, and customer-specified control platforms can be integrated for fleet consistency.
What testing is completed before a silent genset is shipped?
Each unit undergoes full-load testing from 0–110% rated capacity, step-load response testing, continuous operation endurance testing, voltage and frequency stability testing, and emergency protection verification, alongside incoming, assembly and electrical safety checks.
How is maintenance handled on an enclosed unit?
Canopy doors give access for daily inspection and servicing. We supply genuine engine, alternator, control and filter parts, and provide installation guidance and technical troubleshooting support after commissioning.
Can you produce silent sets to our own brand and specification?
OEM and ODM production is part of our manufacturing programme. We customize power range, engine brand, electrical configuration, control system, acoustic design and operating mode according to project requirements and the application environment.