Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine Diesel Generator By Engine
Wholesale MTU Powered Diesel Generator Sets
Home / Products / Diesel Generator By Engine / MTU Powered Diesel Generator Sets

MTU Powered Diesel Generator Sets

Complying with ISO 8528 and GB/T 2828 industry standards, these gensets are equipped with authentic MTU high-end industrial engines, high-precision full-copper brushless alternators, and intelligent control systems. Covering a power range from 20kW to 4000kW, the units fully satisfy standby, prime and continuous power requirements. With decades of German industrial core technology and global rigorous field verification, MTU gensets stand out for ultra-stable operation, rapid load response, low fuel consumption and superior environmental adaptability, widely applied in data centers, high-end hospitals, intelligent buildings, petrochemical industries and key national infrastructure projects.

Product Information

Driven by genuine German MTU industrial diesel engines, our generator sets adopt world-renowned German precision manufacturing technology. Featuring supreme operational stability, ultra-low failure rate, and excellent load capacity, they provide top-tier reliable power solutions for high-standard, mission-critical power supply scenarios worldwide.

Core Configuration

Engine: Adopts original German MTU series industrial diesel engines, featuring advanced electronic fuel injection and efficient turbocharged intercooling technology. With an integral rigid block structure and precise industrial calibration, the engine realizes smooth power output and zero-delay load pickup. It operates stably in extreme cold, high temperature, high altitude, humid and salt-spray corrosive environments, with a standardized global after-sales system and ultra-long maintenance cycle.

Alternator: Maintenance-free brushless synchronous full-copper alternator with Class H high-grade insulation and IP22–IP23 protection level. It meets ISO G3 high-precision power quality standards, with extremely low voltage and frequency fluctuation. The stable and pure power output is perfectly compatible with high-precision electronic equipment, server clusters, and sensitive industrial loads.

Control System: Chinese-English dual-language LCD intelligent controller with comprehensive multi-dimensional fault protection. It supports automatic start-stop, ATS automatic power switching, 4G remote monitoring, cloud intelligent management and multi-unit parallel operation, realizing 24/7 unattended intelligent operation.

Auxiliary System: Equipped with a professional closed circulating cooling system, high-precision triple filtration, damping vibration absorbers, high-efficiency muffler and integrated base frame. The modular optimized structure ensures convenient installation, simple daily maintenance, and long-term stable unit operation.

Key Advantages

German Precision & Extreme Reliability

Inheriting strict German industrial manufacturing standards, MTU engines feature a compact, rigid structure and an ultra-low failure rate. Validated by massive high-end global projects, the gensets deliver long-term stable operation and exceptional continuous heavy-load resistance.

Superior Load Response & Power Stability

With precise electronic fuel control and an optimized air intake system, the units achieve rapid full-load response and fluctuation-free power output. It guarantees uninterrupted and zero-error power supply for core critical equipment.

Efficient Fuel Economy & Low Lifecycle Cost

Precision fuel injection technology achieves full combustion and optimized energy efficiency. Thanks to long maintenance intervals and durable overall structure, the gensets effectively reduce long-term operation and lifecycle maintenance costs.

Excellent Extreme Condition Adaptability

The units maintain stable rated power output with negligible attenuation in high altitude, extreme temperature, damp and corrosive coastal environments. Customized cold start, anti-corrosion and dust-proof upgrades are available for special harsh working scenarios.

Eco-Friendly & Versatile Deployment

Fully compliant with China National III/IV non-road emission standards and international mainstream environmental protection regulations. The silent version features noise ≤75dB(A). Multiple configurations, including open-frame, silent canopy, mobile trailer, and containerized types, are optional, supporting personalized customization and multi-unit parallel connection.

Power Range & Applications

500–1000kW: Grade-A hospitals, high-end hotels, municipal key projects, fine chemical factories, and medium industrial parks.

1000–4000kW: Large data centers, petrochemical bases, port terminals, key industrial zones and national core infrastructure power stations.

 

Optional Accessories & Customization

ATS automatic transfer switch, generator paralleling cabinet, 4G remote monitoring and cloud management system; soundproof silent enclosure, rainproof canopy, mobile trailer device, integrated container power station; low-temperature cold-start preheater, enlarged fuel tank, explosion-proof and anti-corrosion customization; genuine original spare parts and full-lifecycle professional after-sales maintenance services.

Genset Model Genset Prime Power Genset Standby Power  Engine Model Open Type   Dimension(mm) Open Type Weight(kg) Silent Type   Dimension(mm) Silent Type Weight(kg)
kW kVA kW kVA
MTU Series(50HZ)
AWT-M520 480 600  520 650  12V1600G10F 3300*1400*1970 3900 4000*1600*2150 5200
AWT-M570 520 650  570 713  12V1600G20F 3400*1400*1850 4400 4200*1600*2250 5850
AWT-M570 520 650  570 713  12V2000G25 4000*1650*2280 6500 4900*2000*2500 8500
AWT-M700 640 800  700 875  12V2000G65 4200*1650*2280 7000 4900*2000*2500 9000
AWT-M800 728 910  800 1000  16V2000G25 4300*1600*2300 5800 4900*2000*2500 7800
AWT-M880 800 1000  880 1100  16V2000G65 4300*1600*2300 6000 4900*2000*2500 8000
AWT-M1000 900 1125  1000 1250  18V2000G65 4700*2000*2380 9000 5500*2200*2600 11800
AWT-M1100 1000 1250  1100 1375  18V2000G26F 4700*2000*2380 9000 5500*2200*2600 11800
AWT-M1200 1100 1375  1200 1500  12V4000G23R 5500*2220*2660 12000 6500*2600*2800 15500
AWT-M1320 1200 1500  1320 1650  12V4000G23 5500*2220*2660 12500 6500*2600*2800 16000
AWT-M1650 1500 1875  1650 2063  12V4000G63 5500*2220*2660 13000 6500*2600*2800 16500
AWT-M1880 1600 2000  1800 2250  16V4000G23 6500*2600*2680 17000 7500*2800*3000 21000
AWT-M2000 1800 2250  1980 2475  16V4000G63 6500*2600*2680 17500 7500*2800*3000 21500
AWT-M2200 2000 2500  2200 2750  20V4000G23 8300*2950*2700 20500 / /
AWT-M2500 2200 2750  2500 3125  20V4000G63 8300*2950*2700 21000 / /
AWT-M2750 2500 3125  2750 3438  20V4000G63L 8300*2950*2700 21000 / /
MTU Series(60HZ)
AWT-M700 635 794  700 875  12V2000G45 4200*1650*2280 6000 4900*2000*2500 8000
AWT-M800 728 910  800 1000  12V2000G85 4300*1650*2280 6500 5500*2200*2600 9300
AWT-M908 825 1031  908 1135  16V2000G45 4300*1700*2300 7000 5500*2200*2600 9800
AWT-M1000 910 1138  1000 1250  16V2000G85 4300*1700*2300 7500 5500*2200*2600 10300
AWT-M1200 1075 1344  1200 1500  18V2000G85 4700*2000*2380 9000 5500*2200*2600 11800
AWT-M1540 1400 1750  1540 1925  12V4000G43 5500*2220*2660 12500 6500*2600*2800 16000
AWT-M1800 1630 2038  1800 2250  12V4000G83 5500*2220*2660 12500 6500*2600*2800 16000
AWT-M2080 1890 2363  2080 2600  16V4000G43 6500*2600*2680 17500 7500*2800*3000 21500
AWT-M2350 2130 2663  2350 2938  16V4000G83 6500*2600*2680 17500 7500*2800*3000 21500
AWT-M2530 2300 2875  2530 3163  20V4000G43 8000*2950*2700 20500 / /
AWT-M2800 2545 3181  2800 3500  20V4000G83 8200*2950*2700 20500 / /
AWT-M3090 2810 3513  3090 3863  20V4000G83L 8300*2950*2700 20500 / /

About Aiweite

Founded in 2008, Yangzhou Aiweite Electromechanical Co., Ltd. has accumulated extensive experience in the manufacture and installation of generator sets ranging from 1 kVA to 2,500 kVA. We are China MTU Powered Diesel Generator Sets Manufacturers and Wholesale MTU Powered Diesel Generator Sets Factory. Over the years, Aiweite has continued to strengthen its capabilities and market presence, and we are committed to becoming a reliable long-term partner for customers worldwide.

Through continuous innovation, we consistently improve the efficiency, durability, and environmental performance of our products. Advanced manufacturing equipment and strict quality management are applied throughout production to ensure that every generator set meets applicable international standards.

We have established long-term and stable relationships with customers across different markets and place strong emphasis on customer satisfaction. Comprehensive support is provided before, during, and after each project, ensuring that customer requirements are addressed promptly and effectively.

Guided by the principle of "Quality First, Customer First," we uphold a corporate culture built on integrity, responsibility, innovation, and mutual success.

Yangzhou Aiweite Electromechanical Co., Ltd.

Latest Updates

  • 1000-2500 kVA Universal Diesel Generator Sets: Key Procure...
    An 1800 kVA standby-rated diesel generator set cannot feed a 1500 kW process line hour after hour. Under ISO 8528-1:2018, the standby rating assumes emergency duty only, limits the 24-hour average load to 70% of rated output, and permits no planned overload; the same machine configured for prime d...

    Oct 09, 2026

  • 1000-2500 kVA Universal Diesel Generator Sets: Large-Scale...
    Losing power for thirty minutes can shut a production line, stop a pumping station, or force a process restart that wastes hours. When the required capacity reaches 1000-2500 kVA, a universal diesel generator set is not a small accessory; it is a major electrical asset that must be specified, inst...

    Oct 07, 2026

  • Baudouin Powered Diesel Generator Sets: Key Performance Fa...
    A petrochemical plant in Southeast Asia shortlisted two Baudouin powered diesel generator set packages for a 600 kVA standby application. The winning quotation had to prove four things: duty rating, derating behaviour, fuel consumption curve and control response. Those four factors separate a gene...

    Sep 28, 2026

Contat Us

MTU Powered Diesel Generator Sets Industry knowledge

MTU Powered Diesel Generator Sets from Yangzhou Aiweite

Yangzhou Aiweite Electromechanical Co., Ltd. manufactures MTU Powered Diesel Generator Sets for data centers, hospitals, petrochemical plants and national infrastructure where a single outage is unacceptable. We integrate genuine MTU industrial diesel engines with high-precision full-copper brushless alternators and intelligent control systems, covering 20kW to 4000kW in standby, prime and continuous duty.

Every unit is assembled in our Yangzhou factory under ISO 8528 and GB/T 2828 process controls, then full-load tested before dispatch. Our engineering team configures each set around the load profile, site environment and electrical interface you specify.

Why MTU Engines Suit Mission-Critical Power

MTU industrial engines use electronic fuel injection and turbocharged intercooling with an integral rigid block. The result is smooth power delivery, fast load pickup and stable output in cold, hot, high-altitude, humid and salt-spray conditions. Aiweite pairs these engines with maintenance-free brushless synchronous alternators rated Class H insulation and IP22–IP23 protection, meeting ISO G3 power quality for sensitive server, medical and process loads.

  • Engine: Original German MTU series, electronic fuel injection, turbocharged intercooling.
  • Alternator: Full-copper brushless synchronous, Class H insulation, IP22–IP23.
  • Control: Chinese-English LCD intelligent controller with multi-dimensional fault protection.
  • Auxiliary: Closed circulating cooling, triple filtration, damping absorbers, high-efficiency muffler, integrated base frame.

Available Range and Configuration Options

Our MTU range spans 20kW to 4000kW. Standard builds are available as open-frame, silent canopy (≤75dB(A)), mobile trailer and containerized power stations. Electrical configuration supports 50Hz or 60Hz and global voltage standards, with control systems from Deep Sea, SmartGen, ComAp or a customized platform.

Configuration Typical Power Band Application Fit
Open type 500–4000kW Plant rooms, industrial parks, retrofit projects
Silent type 500–2500kW Hospitals, hotels, urban buildings, noise-sensitive sites
Trailer type 500–1000kW Mobile backup, construction, temporary events
Container type 1000–4000kW Data centers, petrochemical bases, port terminals

Optional accessories include ATS automatic transfer switches, generator paralleling cabinets, 4G remote monitoring and cloud management, low-temperature cold-start preheaters, enlarged fuel tanks, and explosion-proof or anti-corrosion upgrades.

Model Reference: 50Hz MTU Series

The table below shows representative 50Hz models from our MTU series. Prime and standby ratings follow ISO 8528 definitions; dimensions and weights are for standard open and silent builds.

Model Prime kW/kVA Standby kW/kVA Engine
AWT-M520 480/600 520/650 12V1600G10F
AWT-M700 640/800 700/875 12V2000G65
AWT-M1000 900/1125 1000/1250 18V2000G65
AWT-M1650 1500/1875 1650/2063 12V4000G63
AWT-M2200 2000/2500 2200/2750 20V4000G23
AWT-M2750 2500/3125 2750/3438 20V4000G63L

60Hz models are available across the same power bands with matched engine and alternator combinations. For the full model list, see our Diesel Generator By Engine range.

Application Fit by Power Band

MTU sets are selected by load criticality and site conditions rather than by size alone. Our engineering team maps each project to the appropriate band:

  • 500–1000kW: Grade-A hospitals, high-end hotels, municipal key projects, fine chemical factories and medium industrial parks.
  • 1000–4000kW: Large data centers, petrochemical bases, port terminals, key industrial zones and national core infrastructure power stations.

For projects outside these bands, our Diesel Generator By Power Range covers 10kVA to 2500kVA in universal configurations, and our Diesel Generator By Structure range details enclosure and mobility options.

Controls, Automation and Parallel Operation

Our intelligent controllers support automatic start-stop, ATS automatic power switching, 4G remote monitoring and cloud management. Multi-unit parallel operation is available for larger plants, with load sharing and synchronization handled by the control system. The controller interface is configured to match your SCADA, BMS or plant DCS protocol so that alarms, status and metering data reach the operators who need them.

For data centers and hospitals, we typically supply the genset with an integrated paralleling cabinet and ATS, tested as a system before shipment. This reduces on-site interface risk and shortens commissioning time.

Installation, Utilities and Site Requirements

MTU sets are heavy and require a stable foundation, adequate combustion and cooling air, and exhaust routing that meets local code. Our documentation package includes foundation loading data, air and exhaust flow requirements, fuel system schematics and cable entry details. For containerized units, we provide the container outline, lifting points and internal layout so civil works can proceed in parallel with manufacturing.

  • Foundation and vibration isolation details
  • Combustion air, cooling air and exhaust back-pressure limits
  • Fuel supply, return and day-tank sizing
  • Power cable sizing and control cable schedule
  • Earthing and neutral configuration

Quality Control and Acceptance Testing

Every Aiweite MTU set passes incoming inspection of key components, assembly process verification, electrical safety checks and mechanical fitting inspection. Before dispatch, each unit undergoes full-load testing from 0–110% rated capacity, step load response testing, continuous operation endurance testing, voltage and frequency stability testing, and emergency protection system verification.

We can support third-party inspection and provide test reports, wiring diagrams, operation manuals and maintenance schedules as part of the delivery scope. Our factory operates under ISO 9001 and ISO 14001 management systems.

Information We Use to Configure Your Solution

To prepare an accurate configuration and quotation, we need the following project inputs. The more detail you provide, the closer the first proposal will be to the final build.

  • Site location, altitude, ambient temperature range and humidity
  • Required prime, standby or continuous power in kW or kVA
  • Load profile, including motor starting and non-linear loads
  • Voltage, frequency, phase and neutral configuration
  • Enclosure preference: open, silent, trailer or container
  • Control system brand and communication protocol
  • ATS, paralleling or remote monitoring requirements
  • Fuel storage, exhaust routing and emission limits
  • Delivery destination, site access and lifting constraints

Maintenance, Spare Parts and Serviceability

MTU engines are designed for long maintenance intervals, and our modular base frame layout keeps filters, belts and service points accessible. We supply genuine engine components, alternator parts, electrical and control system parts, filters and consumables to support long-term operation. Our support team provides installation guidance, operation support and technical troubleshooting after commissioning.

For projects requiring extended service coverage, we can prepare a spare parts list matched to your maintenance schedule and site conditions.

Frequently Asked Questions

What power range do your MTU powered diesel generator sets cover?

Our MTU range covers 20kW to 4000kW, with standard 50Hz and 60Hz models from 480kW prime up to 2500kW prime. Larger and smaller configurations are available on request.

Can you supply a complete containerized power station with ATS and paralleling?

Yes. We build containerized MTU power stations with integrated ATS, paralleling cabinets and remote monitoring, tested as a system before shipment.

What testing is performed before delivery?

Each set undergoes full-load testing from 0–110% rated capacity, step load response testing, continuous operation endurance testing, voltage and frequency stability testing, and emergency protection verification.

Do you support OEM or ODM customization for MTU gensets?

We provide OEM and ODM manufacturing based on your specifications, including power configuration, engine selection, control system integration and structural design.

What information do you need to prepare a quotation?

We need site conditions, required power, load profile, voltage and frequency, enclosure preference, control and communication requirements, and delivery destination. Our engineering team will confirm the configuration and provide a proposal.

How do you support maintenance after commissioning?

We supply genuine spare parts, filters and consumables, and provide installation guidance, operation support and technical troubleshooting. Spare parts lists can be prepared to match your maintenance schedule.